Fujitsu AC Error Codes Guide – Meanings, Causes & Fixes

By Be Cool Air Conditioning 6 min read

Fujitsu Air Conditioning Error Codes

When your Fujitsu air conditioner shows an error code, it’s trying to tell you something’s not right — a sensor, communication line, power supply, or mechanical part has detected a fault. Knowing what the codes mean helps you fix small issues quickly and decide when it’s time for a technician.

How Error Codes Work in Fujitsu ACs

  • Fujitsu units have built-in diagnostics. The indoor unit or remote control often displays codes like E:01, 11.2, or blinking sequences of LEDs.
  • Some codes are stored in memory; others show in real time. You may have to press certain buttons (e.g. “CHECK”, “SELECT”, or “SET TEMP”) to view codes.
  • Codes usually point to one of these categories: communication / wiring, sensor or thermistor faults, fan / motor / compressor or mechanical faults, overheat / pressure protections, indoor vs. outdoor unit mismatches or capacity issues, etc.

Complete List of Error Codes and What They Mean

Here are many of the Fujitsu error codes commonly used, what they typically indicate, and some things to check. This list draws on Fujitsu’s trouble-shooting PDFs and technical sources.

CodeWhat It Means / Description
E:00Communication error: indoor unit ↔ remote control.
E:01Communication error: indoor unit ↔ outdoor unit.
E:02Room (indoor) temperature sensor open circuit.
E:03Room temperature sensor short circuit.
E:04Indoor heat exchanger / pipe sensor open.
E:05Indoor heat exchanger / pipe sensor shorted.
E:06Outdoor (or outdoor “exchanger”) pipe / heat exchanger sensor open.
E:07Same sensor short circuit (outdoor exchanger) or similar.
E:08Power source connection failure.
E:09Float switch operated / water detection / drainage issue.
E:0A / 0AOutdoor temperature sensor open.
E:0BOutdoor temperature sensor short.
E:0CDischarge pipe temperature sensor failure or open.
E:0DDischarge pipe temp sensor short / failure.
E:0EOutdoor high pressure / heatsink error.
E:0FHigh discharge temperature (i.e. discharge sensor reading high).
11Serial / comms error (indoor / outdoor units) in split / ducted systems.
12Remote controller communication error.
18External communication error (could be remote, branch, or other module).
1ACompressor failure.
1BOutdoor fan motor failure.
1CInverter to PCB communication error.
1DTwo-way (or multi-way) valve sensor failure.
1EExpansion valve error.
1FConnection ID Unit error (indoor likely).
22Indoor unit capacity abnormal (e.g. mismatch vs outdoor unit, or config error).
24Excessive high pressure protection is triggered in cooling mode.
25PFC circuit error (Power Factor Correction / supply electronics).
26Indoor unit address setting error (wired remote or multiple indoor units).
27Indoor signal error.
28Indoor heat exchanger temperature error.
29Wired remote / connection unit number error.
3AIndoor unit communication circuit (wired remote) error.
41Indoor room-temperature thermistor / sensor failure.
42Indoor heat exchange temp thermistor error.
51Indoor fan motor error (often fan motor failure or blocked fan).
53Indoor water drain abnormal (blocked, float switch, or overflow).
57Indoor damper error.
58Intake grille / louvre position error or grille stuck.
62Outdoor unit main PCB error.
64Outdoor unit Active Filter / PFC circuit error.
65IPM error (inverter / power module) outdoors.
71Outdoor discharge temperature thermistor error.
72Outdoor compressor temperature thermistor error.
73Outdoor heat exchange temperature thermistor error.
74Outdoor air temperature thermistor error.
76Outdoor operating valve thermistor error.
77Outdoor unit heat sink temperature thermistor error.
86Outdoor pressure sensor error.
94Outdoor unit trip detection (protection mode).
95Outdoor compressor motor control error.
97Outdoor fan motor 1 error.
99Outdoor 4-way valve error.
A1Outdoor discharge temperature 1 error.
A3Outdoor compressor temperature error.

What Triggers These Errors

Here are the common causes behind those codes:

  • Sensor failures / thermistor issues: wires disconnected, sensor damaged, moisture ingress, corroded connection.
  • Communication problems: indoor/outdoor units not talking properly, remote control errors, mis-wired multi-indoor systems.
  • Mechanical faults: fan motor stuck or damaged, compressor not starting, valve actuator or damper/motor failures.
  • Power issues / electronics: supply voltage too low or high, faulty PCBs, IPM (inverter module) malfunction, PFC circuits failing.
  • Pressure / temperature extremes: excessively high discharge temperatures, overpressure in refrigerant circuits, heat sink issues, etc.
  • Drainage / water issues: float switch triggered, blocked condensate line, water overflow.

Troubleshooting & Fixes You Can Try

Here are steps you can take to resolve many of these codes, assuming it’s safe for you to do so:

  1. Power-cycle / Reset
    • Turn off unit via remote.
    • Switch off the breaker or isolator. Wait a few minutes.
    • Turn back on. Sometimes resets the system and clears transient errors.
  2. Inspect Sensors & Wiring
    • Open panel (if safe) and look for loose connectors on sensors.
    • Check wiring between indoor & outdoor units.
    • Replace any damaged sensors/terminals.
  3. Check Filters, Fans, and Airflow
    • Clean or replace air filters.
    • Remove debris around and inside outdoor unit.
    • Ensure fans spin freely (no obstruction).
  4. Check Refrigerant Pressure / Discharge Conditions
    • If discharge temp is too high or pressure protection trips, ensure the condenser coil is clean.
    • Check refrigerant levels (this usually means calling in a licensed HVAC tech).
  5. Check Remote and Communication Lines
    • Replace batteries in remote.
    • Ensure remote control is correctly paired.
    • For wired remote / multi-indoor systems, check address / signal wiring.
  6. Inspect Control Boards / Electronics
    • Check for visible burning, corrosion, or component damage.
    • Ensure good power supply. If IPM or PCB components are damaged, those usually need professional repair/replacement.
  7. Drainage / Water-Related Checks
    • Ensure condensate drains are clear.
    • Check float switch functionality.
    • Ascertain the drain pan isn’t overflowing or cracked.

When to Call a Technician

Some errors are too dangerous or complex to fix as a DIY job. You should call a qualified Fujitsu / HVAC technician in cases like:

  • Compressor failure codes (e.g. 1A) or major mechanical failures.
  • High pressure / discharge temperature protection repeatedly triggering.
  • Electronic board failures (IPM, PCB) or PFC circuit faults.
  • Refrigerant leaks or pressure repairs (licensed handling required).
  • Warranty or safety-covering issues (so you don’t void warranty).

Tips for Preventing Fujitsu AC Errors

  • Regular maintenance (filter cleaning, coil cleaning, keeping outdoor unit free from leaves/obstructions).
  • Keep sensors and their housings clean, dry, and protected from elements.
  • Ensure correct installation (correct pipe routing, wiring, remote addressing).
  • Ensure stable electrical supply; use surge protection where practical.
  • Have seasonal checkups before hot or cold weather peaks.

Conclusion

Fujitsu AC error codes are powerful tools to help diagnose problems before they become big, expensive repairs. With this full guide, you can understand what each code usually means, try simple fixes where safe to do so, and know when to call in professional help.

If you tell me your exact Fujitsu AC model (e.g. model number from the indoor unit), I can pull up its specific error code list so troubleshooting is even more accurate.

Related articles

7 min read

Hitachi AC Error Codes : Detailed Guide

Hitachi air conditioners use error or alarm codes to indicate when something is out of spec—sensor failure, communication faults, safety devices tripped…

Read article

6 min read

Toshiba AC Error Codes – Full Guide

Toshiba air conditioners have built-in self-diagnosis. When the unit detects a fault whether in sensors, communication, fans, compressor, pressure, or PCB—it…

Read article

Need air conditioning sorted?

Tell us what you need and we will come back to you with honest advice and a clear, written quote.

Call nowFree quote